Table of Contents
- General Information
- Intended Use
- Ambient Conditions
- Transport and Storage
- Safety
- Machine Description
- Commissioning
- Operation and Adjustments
- Maintenance
- Troubleshooting
- Spare Parts
- Contact Mac-Tech
General Information
- Manufacturer: Erbend Makina Sanayi ve Ticaret A.Ş.
- Website: erbend.com
- Intended for trained personnel for installation, operation, and maintenance.
Intended Use
- EMS Motor Operated Guillotine Shears are designed for metal sheet cutting in series production.
- These machines reduce labor costs and improve cutting efficiency.
- Only trained personnel should operate, maintain, and repair the machine.
- Deactivation of safety equipment voids warranty and liability.
Ambient Conditions
- Operating temperature: +5°C to +40°C.
- Relative humidity: 30% to 95%, no condensation allowed.
- Machine must be used in a covered area, protected from sunlight and rain.
Transport and Storage
- Use lifting lugs marked on the machine for safe lifting.
- Transportation should be done with a crane; forklifts are not recommended.
- Store the machine in a dry, dust-free environment to prevent damage.
Safety
- Follow all occupational safety regulations.
- Do not modify machine components or disable safety devices.
- Ensure all warning labels and emergency stop functions are in place.
- Only trained and qualified personnel should operate the machine.
Machine Description
- EMS series models: EMS 2030, EMS 2625, EMS 3220, EMS 4215.
- Features include back gauge system, clamping beam, and motorized shearing system.
- Electrical and air connections should be made according to machine specifications.
Commissioning
- Ensure the machine is installed on a stable and level foundation.
- Connect electrical and pneumatic systems according to specifications.
- Perform leveling and fixing before operating the machine.
Operation and Adjustments
- Modes include single mode, manual mode, and program mode.
- Adjustments for clamping, blade position, and back gauge should be performed as needed.
- Foot switch operation is required for certain functions.
Maintenance
- Follow the maintenance schedule for lubrication and inspections.
- Lubricate guide shafts, back gauge systems, and drive bearings regularly.
- Check toothed belt tension and adjust as necessary.
Troubleshooting
- Common issues include misalignment, motor faults, and shearing defects.
- Refer to the user manual for error codes and troubleshooting steps.
- Perform routine checks on electrical connections and hydraulic components.
Spare Parts
- Includes machine components, pneumatic circuit drawings, and electrical parts.
- Only use original manufacturer spare parts for repairs.
Contact Mac-Tech
Address: 8397 N 87th St, Milwaukee, WI 53224
Phone: 414-486-9700
Email: win@mac-tech.com
Website: mac-tech.com
Get Weekly Mac-Tech News & Updates