Overview
Before choosing an Erbend MFC for repeat rake trim, have it fold both open hems on your longest production blank. The finished trim should seat on the SCCL trim cleat and SCZC zee closure without forcing or reshaping.
- Run the trial in the specified metal, thickness and coating. Check that the first return clears the tooling during the second fold, the hem gaps stay consistent end to end and the exposed face stays unmarked.
- Set the actual cleat and zee to the spacing and orientation in the approved pitch-specific section. Check that both hems engage evenly. If the detail calls for a lap, fold a second piece at the same settings and check the overlap after any specified end preparation.
- Size the quote for your longest blank and specify the tooling and control package used in the trial.
- Use factory trim where specified and evaluate shop folding only where the approved detail permits it. A bench fit does not establish equivalent roof-system performance or warranty coverage.
Consider the Erbend MFC for repeat runs of rake trim if it can fold both open hems on a full-length blank in your production stock and the finished piece seats on the cleat and zee closure without forcing or reshaping.
Central States’ Central Shield 150 was announced on November 12, 2026. The standing-seam roof panel has a 1.5-inch rib, uses concealed clips and snaps together without mechanical field seaming of the panel joints. The flashing along the sloped gable edge is a separate fit problem. In the residential rake detail, one open hem hooks over the SCCL trim cleat and the other over the SCZC zee closure. The installation guide gives pitch-specific instructions, so base the demonstration on the approved project section.
Fit both hems on the same full-length sample
Run the longest pre-cut blank you expect to fold, in the specified metal, thickness and coating. The MFC’s clamping beam holds the sheet while the folding beam bends the projecting edge. Once the first return is formed, watch where the blank registers against the backgauge and whether that return clears the tooling while the second hem is formed. Inspect the exposed face for scuffs or pressure marks. A short coupon can help establish a bend, but it cannot show whether the hem gaps stay consistent along the full length.
Set the actual cleat and zee at the spacing and orientation shown in the approved section. A piece can match the outside profile and still bind or lift off one edge when you seat the other. Check that both returns engage evenly along the length without twisting the flashing or prying a hem open to make it fit. If the detail calls for a lap, fold a second piece at the same settings and check the overlap after any specified end preparation.
Quote the MFC setup that made the sample
The Erbend MFC combines a motorized folding beam, a standard servo backgauge and Erfold Basic line-by-line CNC control. Basic can save the bend sequence, backgauge positions and open-hem steps so the operator can repeat the profile without laying out each blank by hand. Record the folding-beam setting used in the trial: the standard beam adjustment is manual.
The MFC family has published sheet lengths of 2,050, 2,550 and 3,200 mm. Size the quote for the longest blank you need to fold and specify the tooling and control package used in the trial. Optional Erfold Advanced adds graphical programming and bend-sequence simulation to help spot possible tool interference. It does not prove that the quoted setup can hold the required hem gap or leave the finish unmarked.
If high-eave flashing also recurs in your shop, test that pitch-specific section separately. In the Central Shield 150 high-eave detail, an open return hooks over a continuous cleat and the other edge fastens to the zee. That different shape can change which bends clear the tooling.
Keep trim approval separate from machine fit
Use factory trim where specified, and evaluate shop folding only where the approved detail permits it. A bench fit shows how the sample engages the mating parts. It does not establish equivalent roof-system performance or warranty coverage.
I’m Patrick O’Neill, Mac-Tech’s National Product Manager and Regional Sales Executive. Bring the approved section showing the pitch, hem gaps and return depths, along with the actual cleat and zee, representative coated blanks, your longest blank length and typical run quantities. I can help identify the bends and gauging steps the demonstration needs to prove and match the MFC working length, tooling and controls to your work for a quote.
Sources
- Central States Introduces Central Shield 150 Standing Seam Roof Panel
- Central Shield 150 snap-lock standing seam roof panel
- Central States Introduces Central Shield 150 Snap-Lock Standing Seam Roof Panel That Installs Without Field Seaming Equipment
- Central Shield 150 Residential Roofing Installation Details
- Central Shield 150 Product Guide
- MFC CNC Motorized Sheet Metal Folding Machine
- Erfold Advanced 2D/3D
- ERBEND MFC INDUSTRIAL FOLDING MACHINE
Get Weekly Mac-Tech News & Updates